2013 New 10W airflow monitor with CE
New LC013 LCF013 Airflow Meter,Airflow Monitor,New Stego airflow monitors,2013 New industrial airflow monitor,Newest model airflow monitor,High quality airflow monitors 10W,Airflow monitor LC013 LCF013,2012 NEW Hot Sale Airflow Monitor,Mini 10W air flow monitor,New Best Airflow Monitors in China,New CE Airflow Monitor,2013 New Stego Air Flow Sensor Monitor,LC013 Air Flow Meter Sensor
Mechanical switch contact Versatile fields of applicationSmall sizeEasy to connect
The airflow monitor (NC / NO) is designed to indicate the loss of air movement of a fan or filter fan. The contact detects the loss of air movement caused by fan failure or blocked filter media regardless of direction of air. Its simple mechanical operation makes it a viable alternative to electronic monitoring systems.
Technical Data
Contact type | reed / magnet contact |
Normally closed (NC) | switch contact open when air is flowing |
Normally open (NO) | switch contact closed when air is flowing |
Max. switching voltage | NC: 240VDC (UL), 240V AC/DC (VDE) / NO: 60VDC |
Max. switching current | NC: DC 500mA / NO: DC 170mA |
Max. switching capacity | 10W (resistive load) |
Switching threshold of airflow velocity | > 2.5m/s (hysteresis: > 1m/s) |
Max. airflow velocity | 50m/s |
Contact resistance | < 370mOhm (with wire) |
Max. air humidity | 70% RH (not precipitating) |
Service life | > 100 000 cycles |
Connection | 2 x single strand AWG 28, length 500mm, tip of stranded wire 5mm stripped and tinned (NC: black, NO: blue) |
Mounting | alternatively integrated in protective grille (see table), mounting clamp or mounting clip |
Casing | plastic according to UL94-HB, black |
Fitting position | bidirectional tab perpendicular to airflow |
Operating/Storage temperature | -20 to +50°C (-4 to +122°F) / -20 to +80°C (-4 to +176°F) |
Protection type | IP20 |
Approvals | VDE + UL File No. E250507 |
Note | The product of switching voltage and switching current must not exceed 10W. The max. voltage and max. current must not be exceeded, not even short-term (voltage/current peaks). The resulting voltage and current peaks of inductive or capacitive loads must be restricted by a contact protection circuit. |
Description | Art. No. (NC) | Art. No. (NO) | Dimensions | Weight (approx.) |
Airflow monitor with mounting clamp and mounting clip LC 013 | 01300.0-00 | 01300.1-00 | 34 x 17.5 x 7.5mm | 5g |
Airflow integrated in protective grille (plastic) LCF 013 | 01301.0-00 | 01301.1-00 | 80 x 88 x 10.5mm | 20g |
Airflow integrated in protective grille (plastic) LCF 013 | 01302.0-00 | 01302.1-00 | 92 x 92 x 10mm | 20g |
Airflow integrated in protective grille (plastic) LCF 013 | 01303.0-00 | 01303.1-00 | 120 x 120 x 10mm | 30g |
Technical Data
Contact type | reed / magnet contact |
Normally closed (NC) | switch contact open when air is flowing |
Normally open (NO) | switch contact closed when air is flowing |
Max. switching voltage | NC: 240VDC (UL), 240V AC/DC (VDE) / NO: 60VDC |
Max. switching current | NC: DC 500mA / NO: DC 170mA |
Max. switching capacity | 10W (resistive load) |
Switching threshold of airflow velocity | > 2.5m/s (hysteresis: > 1m/s) |
Max. airflow velocity | 50m/s |
Contact resistance | < 370mOhm (with wire) |
Max. air humidity | 70% RH (not precipitating) |
Service life | > 100 000 cycles |
Connection | 2 x single strand AWG 28, length 500mm, tip of stranded wire 5mm stripped and tinned (NC: black, NO: blue) |
Mounting | alternatively integrated in protective grille (see table), mounting clamp or mounting clip |
Casing | plastic according to UL94-HB, black |
Fitting position | bidirectional tab perpendicular to airflow |
Operating/Storage temperature | -20 to +50°C (-4 to +122°F) / -20 to +80°C (-4 to +176°F) |
Protection type | IP20 |
Approvals | VDE + UL File No. E250507 |
Note | The product of switching voltage and switching current must not exceed 10W. The max. voltage and max. current must not be exceeded, not even short-term (voltage/current peaks). The resulting voltage and current peaks of inductive or capacitive loads must be restricted by a contact protection circuit. |
Description | Art. No. (NC) | Art. No. (NO) | Dimensions | Weight (approx.) |
Airflow monitor with mounting clamp and mounting clip LC 013 | 01300.0-00 | 01300.1-00 | 34 x 17.5 x 7.5mm | 5g |
Airflow integrated in protective grille (plastic) LCF 013 | 01301.0-00 | 01301.1-00 | 80 x 88 x 10.5mm | 20g |
Airflow integrated in protective grille (plastic) LCF 013 | 01302.0-00 | 01302.1-00 | 92 x 92 x 10mm | 20g |
Airflow integrated in protective grille (plastic) LCF 013 | 01303.0-00 | 01303.1-00 | 120 x 120 x 10mm | 30g |