Welcome to ECOL - Join Free - Sign In
Type S DKL Aerosol Fire Extinguishing Device (Console Series)
Type S DKL Aerosol Fire Extinguishing Device (Console Series)
Supplier Info
[China Supplier]
Contact Person : Mr. Yan Frank
Tel : 86-29-88332970
Fax : 86-29-88332680
Product Detail
Aerosol Fire Extinguishing Device

General Description

DKL TYPE-S AUTOMATIC AEROSOL FIRE EXTINGUISHING UNIT is a new class of fixed fire extinguishing system using solid propellant aerosol technology. Unlike conventional fire extinguishing systems, it is stored as a stable solid chemical compound which when activated generates a fire-fighting aerosol. The extinguishing medium however is not stored in a pressurised cylinder. The aerosol is a mixture of gases and micron-sized solids, possessing gas-like distribution properties and long holding times, totally floods the protected enclosure and rapidly extingsuies any fire present.

DKL fire suppression systems, can be characterized as requiring no piping, zero storage pressure, solid-state technology, environmentally friendly, non-conductive & non-corrosive, and has significant space & weight advantages in comparision with gaseous systems.

Technical Specification

Note:

According to < Aerosol Fire Extinguishing System> GA499.1-2004

The following details are a representative extract of the technical specification for HANGING series fire suppression system and may be subject to change. Complete and current details should be determined from the designated supplier's technical manual/data sheets.

 

Console Series Specification

 

ModelJR4000CJR6000CJR8000CJR100MCJR120MC
Aerosol Mass (g)50007500100001500020000
Generator Mass (kg)4560657075
Max.Protected Volume (m³)406080100120
Dimensions (mm)     Length90090090010501050
                              Width400400400450450
                              Hight800800800920920
Discharge Time (sec)< 80< 100< 110< 110< 110
 

Fire Classes

According to < Code for Design of Gas Fire Extinguishing Systems> GB 50370-2005

-Class A: Electrical Appliance Fire

-Class B: Solid Surface Fire

-Class C: Liquid Fire

 

Minimum Design Factor:

Class B and surface Class A fire: 100g/m3 (Type S aerosol forming composition)

                                                  50g/m3 (Type K aerosol forming compositon)

 

Electrical activation:

-Starting current: 1A

-Starting voltage: 24 VDC

-Min. starting current: 500mA 5ms

-Max. safe current: 250mA 5min

-Linkage mode: series system

 

Canister Characteristics:

-Temperature range:  -20oC - +55oC

-Humidity range of application: 0 - 98% non-condensing

-Service life: ≤ 6 years (depends on installation environment)

-Vibration: 5g @ 50 - 250 Hz

 

Aerosol Characteristics:

-Minimum particle size: -1 micron

-Holding time: ≤ 60 mins

Typical Applications:

-cargo compartments

-data rooms

-electrical substations

-cable tunnels

-generator rooms

-intelligent buildings

-laboratories

-machinery spaces

-raised-floors

-telecommunications cabins

J&R Aerosol Fire Extinguishing Technology Benefits at a Glance

-spontaneous extinguishing action

-cost effective

-compact and weight saving

-tested and certified

-simple to install and recommission

-no pressurised cylinders or pipe work

-environmentally friendly

-low toxicity

Type S DKL Aerosol Fire Extinguishing Device (Console Series)