SAT-8C TDR Cable Fault Locator adopts international advanced electronic measurement technology, which is a compositive instrument that integrates with ATDR, resistance meter, megohmmeter and automatic bridge. It is applicable for localization of breakage, cross, poor electric insulation and other faults of various telephone cables, RF cables and coaxial cables.
English menu, touch colorized screen, easy operationContrast function for 2 waveformsUSB interfaceMegohmmeter and ohmmeter’s functionsBuilt-in 2Ah lithium-ion rechargeable battery
Widely Used
Testing methods of Pulse reflection and intelligent bridge with both full-automatic and manual testing functions.Testing for insulation resistance and loop resistance. The range of insulation resistance :0~~50MΩAutomatical detection the line status: breakage, cross, poor electric insulation and the high voltage of the lineDAGC(Digital Automaitc Gain Control) and DWAR (Digital Waveform Automatic Recognize) can automatically recognize the waveforms unable to be judged by manual testing.Field calibration function (unknown cable parameter: speed or diameter; correction for distance of cable, automatic memory the correction result); the correction cable functionAdapt for 0.32mm,0.4mm,0.5mm,0.6mm’s telephone cablesMemory stores 10 testing waveforms. Measurement result can upload to PC, and take it for consulting, analyzing and printing
Technical parameters
Pulse reflection testing method
| Full-automatic measurement range | 0~8 km |
Testing accuracy
| 1 m for measurement range: ≤ 2 km. Accuracy: ±2%. | |
8 m for measurement range: ≥ 2 km. Accuracy ±2% | ||
Testing dead zone | 0 km | |
Pulse width | 60ns-10μs automatic adjustment | |
Wave velocity | 0 ~ 300 m /μs | |
Vertical gain | Range: 80 dB. Accuracy: 1 dB. | |
Impedance | 135 Ω (accuracy 1% ) | |
Bridge testing method | Testing range for Poor insulation resistance | 0~50MΩ |
Testing length | Full length 9999m | |
Sectional 9999m×3 sections | ||
Testing error rate | 1% × Full length of line | |
DMM Technical index |
Insulation resistance | 0 ~ 50MΩ |
Minimum resolution:10 kΩ. Accuracy: ±3% | ||
Loop resistance
| 0 ~ 9 kΩ. | |
Minimum resolution: 0.1 kΩ, Accuracy: ±3% | ||
Voltage | AC/DC voltage 0 ~ 250V. | |
Minimum resolution 0.1V, Accuracy: ±5% | ||
Capacitance | 0-1.3uF. | |
Minimum resolution: 1nF, Accuracy: ±5% | ||
Power supply | AC Power | External AC power supply / Charger |
Working time | 6 hours at most | |
Charging time | 4 hours | |
Dimensions(L x W x H) | 220 m m x 162 mm x 48mm
| |
Weight | 950g | |
Working temperature | -10~ 50 °C | |
Storage temperature | -30~ 70 °C | |
Humidity
| 5%-90%(non-condensing) |
SAT-8C TDR Cable Fault Locator