Technical data:
Work pressure: 0.05Mpa—1Mpa , Ideal pressure: 0.1Mpa—0.5Mpa
Standard pressure: Dynamic pressure0.3±0.02Mpa.
Cold water supply temperature: 8-28°C
Hot water supply temperature: 55-85°C
Advice water supply temperature: 55-70°C
Out water temperature range: 20-50°C
Safety temperature : 38°C
Temperature accuracy: Kept constant ±1°C for the setting.
Out water temperature stability: when the temperature of water intake kept constant, Cold
water or hot water pressure change 50% , the outlet water temperature changes in ±2°C of
setting temperature. The supply water pressure kept constant; the temperature for hot water
supply can be increases from 60°C to 75°C(5°C/min), the outlet water temperature changes
in ±2°C of setting tempera.
thermostatic mixer valve core