CE approved 6-Parameter Patient Monitor with 15-INCH screen/ Dual-IBP/ Side-stream Etco2/ Thermal printer
CE approved 6-Parameter Patient Monitor with 15-INCH screen/ Dual-IBP/ Side-stream Etco2/ Thermal printer
Supplier Info
[China Supplier]
Contact Person : Ms. Wang Jenny
Tel : 86-10-51290013
Fax : 86-10-59812390
Product Detail
Multi-parameter patient monitor ECG, NIBP, SPO2, TEMP, RESP, PR Optional Etco2/dual-IBP working with CMS 15-inch monitor Features:   
Ergonomic design, portable, convenient for use 15" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters Unique digital SPO2 technology can work accurate during motion and low perfusion Anti AC & high-frequency electrosurgical & defibrillator’s interference Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation Audible & visual alarm available, adjustable Patient information management function Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room Optional software upgrading based on USB Wired/wireless networking with central monitoring system, up to 64 beds in one group Built-in 3 trace thermal recorder for printing real-time and historical data Multi-language i.e. English, Spanish, Turkish. Super long life rechargeable Lithium battery upto 4 hours of working timeSuitable for adult, pediatrics and neonate patientsStandard configuration:            ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium batteryOptional:             Dual TEMP Dual IBP ETCO2 (side stream)  Thermal recorder Wall mount Trolley Specification: 
  ECG Full lead: I, II, III, AVL, AVR, AVF and VGain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mVScanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/sBand width: 0.05Hz-100Hz(3dB)Heart rate:  Scope: 15 times/minute to 300 times/minutesAccuracy:  ±1 time/minuteVariation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.  Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.    Accuracy: Error rate < 20%          Undetected rate < 20%  ST section  Scope:     ±0.8mVPrecision :  < ±0.05mVSpO2 Detection scope:   0%-100%Accuracy         ±1%     90%-100%                                 ±2%      70%-89%  NIBP  Theory Electric oscillator  Cuff gassing time   less than 15 seconds First-time gassing pressure: dynamic state 24kPa(180 mmHg) Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg), Automatic detection period: 1 minute to 240 minutes  Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 min -90min) and 30min(90 min -240min) Detection scope:  Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg) Detection accuracy  Static pressure: ±3mmHgPulse rate:  ±2%Resp Chest impedance method or concentration of carbon dioxide at end of respiration  Scope of chest impedance method     0 time/minute – 100 minutes/minute  Precision of chest impedance method  time/minute  Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%volDetection scope of respiration rate: 2 times/minute ->60 times/minute(including baby) Detection precision of respiration rate: ±1 time/minute  Temp Single/double path  Type:    Vascular/surface temperature  Scope:    20°C~50°C Accuracy:  ±0.2°C Invasive blood pressure (optional)  Single/double path  Type: direct and continuous detection  Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33kPa(100mmHg) above ±2%Frequency response:DC-12HzInput resistance: not less than 500kSensitivity of sensor: 5μV/V/mmHgMotivation voltage:5V (DC) Accuracy of sensor: ±2%Isolation voltage: 4 kV

 Sensors sockets:

Optional thermal printer 

Accessories:

Optional dual-IBP

Optional Side-stream Etco2 part  

( function(){ var aBigImageSrc = [ 'http://i00.i.aliimg.com/photo/v2/766378120_1/CE_approved_6_Parameter_Patient_Monitor_with.jpg' , 'http://i00.i.aliimg.com/photo/v2/766378120_2/CE_approved_6_Parameter_Patient_Monitor_with.jpg' , 'http://i00.i.aliimg.com/photo/v2/766378120_3/CE_approved_6_Parameter_Patient_Monitor_with.jpg' , 'http://i00.i.aliimg.com/photo/v2/766378120_4/CE_approved_6_Parameter_Patient_Monitor_with.jpg' , 'http://i00.i.aliimg.com/photo/v2/766378120_5/CE_approved_6_Parameter_Patient_Monitor_with.jpg' , 'http://i00.i.aliimg.com/photo/v2/766378120_6/CE_approved_6_Parameter_Patient_Monitor_with.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); CE approved 6-Parameter Patient Monitor with 15-INCH screen/ Dual-IBP/ Side-stream Etco2/ Thermal printer

Ads by Google