Safety Standards
CE Mark, IEC 60601 GB9706
Physical Specification
Dimension:445*95*299mm
Net Weight:4.4kg
Features:
12.1” /15 ” high resolution TFT screen
7ECG leads, maximum 9 waveform display on the same screen
720 hours of the parameter data record and review
2880 groups of the NIBP data record and review
60minutes real time ECG waveform replay
Frozen waveform record, review ad output
Spo2 pulse-tone modulation(pitch tone)
ST analysis, Arrhythmia analysis
Pacemaker detection, defibrillation and high frequency electrsurgical interfernece protection
Complete and flexible mounting solution for transportation and in-patient monitoring
Adapt to intensive care(ICU/CCU)
Wire/wireless to Central Monitoring System
Standard: ECG, RESP, NIBP, SpO2(Guoteng) , TEMP, HR
Optional: Printer, Dual TEMP, EtCO2 , Single/Dual IBP, Nellcor SpO2
DisplayColor TFT 12.1/15 inchResolution: 1024×768 dpiVarious Working Interfaces Selectable:
Standard Monitoring InterfaceBig Font InterfaceFull-screen Multi-lead InterfaceFull-screen multi-lead share interfaceHalf-screen Multi-lead InterfaceOXY-CRG Dynamic InterfaceTrend Concurrence InterfaceNIBP List InterfaceSweep Speed:6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Environment RequirementOperating: Temperature 5-40°C, Humidity≤80%Storage: Temperature -20-55°C, Humidity≤93%
Power SupplyExternal Power Supply: 100-250V AC, 50/60HzBattery Power SupplyType: Built-in Rechargeable Lithium BatteryWorking Period: ≥2 hours
ECGLead Type: 5-lead and 3-lead selectable, detected automaticallyLead Selection: Ⅰ;Ⅱ;Ⅲ;aVR;aVL;aVF;VSweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/sGain Selection:*0.25;*0.5;*1;*2;*4; AutoECG HR Range: 15-350bpmResolution and Accuracy: ±1bpm or ±1%Filter: Diagnostic Mode Monitoring Mode Sugical ModeST-Segment Detection: Alarm Range: -1.2mV-1.2mVST-Segment, Arrhythmia analysis: YesARR Alarm: audible and visual alarm, alarm events recallablePacemaker Detection: Yes, and 5 types abnormal status detectable
RESPSweep Speed:6.25mm/s, 12.5mm/s, 25mm/sMethod: RA-LL impedanceOperation Mode:Auto/ManualMeasurement Range: 1-150 rPMAlarm:Yes, audible and visual alarm, alarm events recallableAccuracy: ±2 rPMApnea Alarm:5-80s
NIBPMethod:Automatic OscillometricOperation Modes: Manual/Automatic/ContinuousAuto measurement time interval: Adjustable1/2/3/4/5/10/15/30/60/90/120/240/480 minutesMeasurement Unit: mmHg/kPa selectableMeasurement Types: Systolic, Diastolic, MeanPressure Range for Adult: Systolic:25-255 mmHg Diastolic:10-220 mmHg Mean:20-235 mmHgPressure Range for Pediatric: Systolic:20-180 mmHg Diastolic: 10-150 mmHg Mean:10-160 mmHgPressure Range for Neonate: Systolic:20-120 mmHg Diastolic: 5-100 mmHg Mean:10-110 mmHgLeak test and pressure auto calibration: YesOver-Pressure Protection: Dual Safety ProtectionResolution: 1mmHgAccuracy: Max mean error:±5mmHgMax standard deviation: ±8mmHgAlarm:Systolic, Diastolic, MeanPR from NIBP: Measurement 40-240bpmResolution: 1bpmAccuracy: 3bpm or 3%Leak test and pressure auto calibration:Yes
SpO2
Excellent measurement of low perfusionAnti interference pf movementMeasurement & Alarm Range:0-100%Resolution: 1%Accuracy: ±2%(80%-100%, Adult/Pediatric) ±3%(60%-79%, Neonate)PR Measurement and Alarm Range: 25-300bpmResolution:1bpmAccuracy: 3bpmRefresh Rate:1s
TEMP
Measurement and Alarm Range: 0-50°CAccuracy: ±0.1°CChannel:Dual ChannelProbe Type: Skin, RectalAlarm: Sound, Light, Text
RecorderBuilt-in Thermal PrinterPrint Width:48mmPrint Speed:12.5mm/s, 25mm/s, 50mm/s
IBPMeasurement Pressure:ART, PA, CVP, RAP, LAP, ICP, P1, P2Measurement and Alarm Range:-30-350 mmHgResolution:1mmHgAccuracy:±2% or ±2mmHgSensitivity: 5μV/V/mmHg; Impedance range: 300-3000Ω
EtCO2
Measurement Method:Side-streamCO2 Range: 0% to 13%CO2 3 mmHg @Accuracy: ± < 5.0% CO2 (at ATPS)< 10% of reading @ > 5.0% CO2 (at ATPS)Breath Rate: 3 - 150 bpmOperating Temperature Range: 5°C to 50°CShipping / Storage Temperature Range: -40°C to 70°CAutomatic Offset Calibration: Time and temperature based, as well as on-demandInput Voltage: 5.00 Volts (± 5%)Interface: Highly configurable serial digital interface, CO2and barometric waveform data, Breath Detect Algorithm dataPneumatics:On-board aspiration pump and flow controllerConfigurable aspiration flows 50 - 250 ml/min (± 10%)Functionality available for H2O trap presence indicatorPower Consumption: 1000 mWatt (typical with pump on) Warm-up Time: 20s Baseline Recovery:5sResponse Time: Detector: 28 mSec (typical) System:100mSec (typical)
Any interesting please contact us, There are many items for your choose!
Include 3.5 inch, 6.4 inch, 7 inch, 8.4 inch, 10.4 inch, 12.1 inch and 15 inch.
12.1/15 inch Patient Monitor GT9003B