Product Detail
Intelligent controller 1.Automatic adaptation 2.Clear,readable display of the state 3.CE standards

Intelligent controller

Application

JKW series reactive power auto compensating controller is suitable for self-adjusting capacitor compensative devices in low voltage distribution increase the efficiency

of the power transformer, reduce line loss, and improve voltage quality. On final aim it will increase the economic and social benefits.

 

 

 

 

 

 

 

 

 

 

 

Function characteristic

Adopt AC sampling technology

 

Digital integration, filtration, not sensitive to the harmony wave.

 

Regard the reactive power as controlling physical quantity; it has high control precision, without input and cut off shaking.

 

 

 

The operation of the full digital of control parameter, easy to use, put in right place in one step, and the data are not lost to have a power failure.

 

Adopt and optimize the excellent control scheme automatically, reduce the times of input and cutoff, improve the service life of system.

 

Strong anti-interference ability can resist 2000V interference pulse from power direct, and not crashing, does not lose the data, it is reliable to run steady.

 

Digital display electric network power factors, reactive power, voltage, current (primary side) and control parameter.

 

With two working modes of manual and automatic is convenient for user to install and debug.

 

With the function of over-voltage, under-voltage judgment and display and fast cutoff capacitor group, prevent capacitor group from running under the over-voltage condition.

 

With the function of available input and cutoff shocking and locking(The user must specify when ordering).

 

With the function for the delay time of the selectable single group capacitor for 200 seconds from cutoff to input, makes capacitor have abundant discharging time after cutoff and reduce capacitor the impact in electric net when putting into again (The user must specify when ordering).

 

The input resistance of current sampling signal is smaller than 0.05 ;it can be taken out from measuring loops directly.

 

Output Loops 1-12 Loop

Technical data

1 Basic Parameter

Rated voltage: AC 380/AC 220 10%

Rated current: AC 0-5A

Rated frequency: 50Hz 5%

 

2 Control Parameter

Sensitivity: 100mA

Targe COS Preset: 0.70-0.99; step length 0.01;

Factory preset 0.98 input and

cutoff time delay: dynamic state 100ms-30S;

Static state 1-250S;

Over-voltage protection: 380-500V/230-260V;

step length 1V; Return difference 6V

Under-voltage protection: 340V/180V;

Return difference 6V

CT variation: 50/5A-3000/5A: step length 1;

Factory preset 500/5A

Capacitance capacity: dynamic state output of each

branch DC12V 50mA

static state output of each branch 380V 7A/200V 5A

 

3 Measuring accuracy

Voltage: 1.0% Current: 1.0%

Power factor: 1.0% Reactive power: 2.0%

 

Size mounting hole

JKWD5 113 X 113mm

 

 