220v power cord cable
Features
1. long time operating temperature for cable conductor is 90 degrees.
2. the highest temperature of the conductor in short circuit (no longer than 5 seconds) in not more than 250 degrees,
if a joint is in the cable, the temperature of the tinning welding joint is not more than 120 degrees, compressing joint not more than 150 degrees and electro-welding joint not more than 250 degrees.
3. no drop in limited provided there is full mechanical tention when cable is laid. It si forbidden to lay cable in iron-pipe or to fix cable by circling around the cable with iron materials.
4. being laid, the minimum temperature of the cable shall not be lower than zero degree. In the case of lower temperature, heating measures shall be taken.
TYPE
1. low voltage cable power cable
Low voltage (0.6/1 kv)
single core or multi-core
copper or aluminium conductor
pvc inusulation
steel tape armored or galvanized steel wire armored or unarmored
pvc outer sheath
power cable
2. medium voltage cabel power cable
Voltage grade is up to 35kv,
cross-section area can be up to 1000 sqmm (copper or aluminiun conductor).
Conductor long-time operating temperature is 90 degrees.
In short circuit, conductor highest temperature should be not more than 250 degrees.
1kv-35 kv
multi-cores
copper or aluminium conductor
xlpe insulation
copper tape or copper wire screen
galvanized steel wire armored
pvc or pe sheath
power cable
3. high voltage cable power cable
High voltage (35kv~220kv)
copper or aluminium conductor
xlpe insulation
metal sheath (lead or corrugated aluminium)
hdpe or pvc outer sheath power cable.
Laying conditions: for lyaing under ground with large different altitude, be able to bear external machanical force and moderate pulling force.
Nominal Area | Calcu- lated Area | Wires | Approx. Overall Diameter | Nominal Breaking Load | Nominal DC Resistance at 20°C | Approx. Weight | Approx. Overall Diameter | Approx. Total Weight | Packing Length | |
No. | Dia. | |||||||||
mm² | mm² | mm | mm | KN | Ohm/km | kg/km | Mm | kg/km | (M+/-5%) | |
10 | 10.02 | 7 | 1.35 | 4.1 | 4.02 | 1.8055 | 90 | 6.1 | 115 | 2000 |
16 | 15.89 | 7 | 1.70 | 5.1 | 6.37 | 1.1386 | 143 | 7.1 | 174 | 2000 |
25 | 24.25 | 7 | 2.10 | 6.3 | 9.72 | 0.7461 | 218 | 8.3 | 256 | 2000 |
35 | 34.36 | 7 | 2.50 | 7.5 | 13.77 | 0.5265 | 310 | 9.5 | 355 | 1000 |
50 | 49.48 | 7 | 3.00 | 9 | 19.84 | 0.3656 | 446 | 11.0 | 501 | 1000 |
50 | 48.35 | 19 | 1.80 | 9 | 19.38 | 0.376 | 437 | 11.0 | 490 | 1000 |
70 | 65.81 | 19 | 2.10 | 10.5 | 26.38 | 0.2762 | 596 | 12.5 | 658 | 1000 |
95 | 93.27 | 19 | 2.50 | 12.5 | 37.39 | 0.1949 | 845 | 14.5 | 920 | 1000 |
120 | 116.99 | 19 | 2.80 | 14 | 48.90 | 0.1554 | 1060 | 16.0 | 1145 | 1000 |
150 | 147.11 | 37 | 2.25 | 15.8 | 58.98 | 0.1238 | 1337 | 17.8 | 1430 | 1000 |
185 | 181.62 | 37 | 2.50 | 17.5 | 72.81 | 0.1003 | 1649 | 19.5 | 1748 | 1000 |
240 | 242.54 | 61 | 2.25 | 20.3 | 97.23 | 0.0753 | 2209 | 22.5 | 2338 | 1000 |
300 | 299.43 | 61 | 2.50 | 22.5 | 120.04 | 0.061 | 2725 | 24.7 | 2870 | 1000 |
400 | 400.14 | 61 | 2.89 | 26 | 160.42 | 0.0456 | 3640 | 28.2 | 3810 | 500 |
500 | 499.83 | 61 | 3.23 | 29.1 | 200.38 | 0.0365 | 4545 | 31.3 | 4739 | 500 |
Application
It is used to transmit and distribute power in power transmission and distribution sysrem of 35kV or lower.It is generally applied to the fields including power,construction,mines,metallurgy,petrochemical industry and communication
Package
As below, or your requirement.
More pictures for your reference, for details, please feel free to contact us.
220v power cord cable