power plants
YuDong -- British PerkinsYP1650 diesel generating sets technical parameters | |
Genset technical parameters | |
Genset model | YP1650 |
Shape dimension/ L x W x H mm | 5970×2775×3310 |
Weight(dry weight) kg | 14080 |
Normal power kVA/kW | 2062.5/1650 |
Standby power kVA/kW | 2250/1800 |
Rated voltage V | 400/230 |
Output frequency Hz | 50 |
The steady-state voltage adjustment rate % | ±1 |
Voltage fluctuation rate % | ≤0.5 |
Frequency volatility % | ≤0.5 |
Load mutations frequency stability of time(S) | ≤3 |
Load mutations voltage stability of time(S) | ≤2 |
Wiring way | Three-phase four-wire |
Control system | Microcomputer control system |
Vibration absorber system | High elastic rubber shock absorbers |
Noise (dB)(1meter) | 106 |
Engine | |
Engine model | 4016TAG2A |
Shape dimension/ L x W x H mm | 3302×1723×2128 |
Weight kg | 5570 |
Power(normal/standby) kW | 1766/1937 |
Type | Sixteen-cylinder,V-shaped, turbocharged |
Oil type | API CD 15W-40 and above |
Fuel type | 0# diesel |
Fuel consumption rate g/kwh | 209 |
Oil consumption rate g/kwh | Fuel 0.5% |
Lubricating oil capacity L | 209 |
Starting mode | DC 24V electric start |
Speed regulation | Electricity adjustable |
Type of cooling | Closed recirculating cooling |
Fan power loss kW | 51 |
Average effective pressure kPa | 2310 |
The piston velocity m/s | 9.5 |
The total capacity of cooling fluid L | 214 |
Inlet flow m3/min | 137 |
Exhaust flow m3/min | 387 |
Exhaust temperature °C | 493 |
Compression ratio | 13.6:1 |
Combustion way | Fuel injection |
Cylinderbore/stroke mm | 160/190 |
Single cylinder displacement L | 3.82 |
The flywheel interface size (the flywheel shell/flywheel) | SAE00/18 |
Generator | |
Model(single bearing) | MX-1790-4 |
Shape dimension/ L x W x H mm | 2150×960×1300 |
Weight kg | 4420 |
Power(normal/standby) kW | 1790/1950 |
Excitation system | Brushless motivated |
Short-circuit current capacity | 300%(3In):10s |
Protection grade | IP21 |
Winding pitch | 2/3 |
The steady-state voltage adjustment rate% | ±0.5% |
Recovery time s | ≤0.5 |
Wave form deviation factor THD | ≤5.0% |
Telephone harmonic factor THF | <2% |
Telephone disturbance factor TIF | <50 |
Control system | |
Control module | Deepsea5110(automatic type) |
Display content | Exchange phase / Line voltage, three-phase currents, the battery voltage, frequency, hydraulic, water temperature, runtime, display alarming fault, engine speed |
Main function | Low speed/speeding alarm, charging failure, abrupt stop input, low hydraulic alarm, high temperature alarm, failed to start,there are three can be set output which is derived from start |