Ads by Google
FEATURES | |
TIA/EIA-568B.2-1;ISO/IEO 11801;NEC/CEC Fire protection – IEC60332-1 (CM) Cable is used for indoor installation | |
CONSTRUCTION | |
Conductor: Bare Solid Copper Conductor Dia.:0.57mm±0.005mm (23AWG) Pair Insulation:Polyethylene Outer Cable Diameter: 6.2 ± 0.2 mm | Pair Identification: Pair1= Blue/White Pair2= Orange/White Pair 3= Green/White Pair4= Brown/White Outer Jacket: PVC Jacket Color:Grey RAL 9002 or as per request |
TECHNICAL CHARACTERISTICS | |
Installation Temperature: 0°C to +60°COperating temperature: -20°C to +75°CDC Resistance Unbalance :5%Pair-to-Ground Capacitance Unbalance :330 pF/100 m Capacitance:14pF/ft nominal | Pulling strength: 130 NMinimum bend radius: 4 outer cable diametersDielectric Breakdown:1000 Volts DC Conductor to ConductorVelocity of Propagation:PE=65%Maximum Skew:45ns@100 meters |
PACKAGING | |
305m/1000ft Easy pulling box; 500m/wooden reel;1000m/wooden reel | |
ELECTRICAL CHARACTERISTICS |
Frequency, MHz | RL | Attenuation, dB | NEXT, dB | PSNEXT, dB | ELFEXT, dB | PSELFEXT, dB |
1 | 20 | 2 | 74.3 | 72.3 | 67.8 | 64.8 |
4 | 20.3 | 3.8 | 65.3 | 63.3 | 55.8 | 52.8 |
8 | 24.5 | 5.3 | 60.8 | 58.8 | 49.7 | 46.7 |
10 | 25 | 6 | 59.3 | 57.3 | 47.8 | 44.8 |
16 | 25 | 7.6 | 56.3 | 54.3 | 43.7 | 40.7 |
20 | 25 | 8.5 | 54.8 | 52.8 | 41.8 | 38.8 |
25 | 24.3 | 9.5 | 53.3 | 51.3 | 39.8 | 36.8 |
31.25 | 23.6 | 10.7 | 51.9 | 49.9 | 37.9 | 34.9 |
62.5 | 21.5 | 15.4 | 47.4 | 45.4 | 31.9 | 28.9 |
100 | 20.1 | 19.8 | 44.3 | 42.3 | 27.8 | 24.8 |
200 | 18 | 29 | 39.8 | 37.8 | 21.8 | 18.8 |
250 | 17.3 | 32.8 | 38.3 | 36.3 | 19.8 | 16.8 |