DZ47, C45N, Schneider Electric, Merlin Gerin 6kA mini circuit breaker
Model No: | DZ47 |
Rated Current: | 1A~63A |
Rated Voltage: | 230Vac(1P), 400Vac(2/3/4P) |
Characteristic Curve: | B, C, D |
No. of Pole: | 1P, 2P, 3P, 4P |
Breaking Capacity: | 6000A |
Standards: | IEC/EN 60898 |
Certificates: | CE,CB |
DZ47 Mini Circuit Breaker MCB
Verified Information
This information is Verified by Bureau Veritas and is valid for the following period:
2012/11/11 --- 2013/11/11
All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >>
Production Capacity:
Product line name
Production Line Capacity
Actual Units Produced(Previous Year)
Miniature Circuit Breaker, Residual Current Circuit Breaker, Moulded Case Circuit Breaker, AC Contactor, Magnetic Starter, Relay |
Miniature Circuit Breaker: 600,000 pcs per month,Residual Current Circuit Breaker: 100,000 pcs per month,Moulded Case Circuit Breaker: 20,000 pcs per month,AC Contactor: 50,000 pcs per month,Magnetic Starter: 10,000 pcs per month,Relay: 10,000 pcs per month |
confidential |
Export Market Distribution:
Market
Revenue(Previous Year)
Total Revenue (%)
North America |
confidential |
0.5 |
South America |
confidential |
6.5 |
Eastern Europe |
confidential |
17.0 |
Southeast Asia |
confidential |
1.0 |
Africa |
confidential |
1.0 |
Oceania |
confidential |
1.0 |
Mid East |
confidential |
7.0 |
Eastern Asia |
confidential |
1.0 |
Western Europe |
confidential |
1.0 |
Central America |
confidential |
1.0 |
Southern Europe |
confidential |
2.0 |
South Asia |
confidential |
1.0 |
Domestic Market |
confidential |
60.0 |
Production Machinery:
Machine Name
Brand & Model No.
Quantity
Number of Year(s) Used
Condition
Punching machine |
JB04-1 |
10 |
10.0 |
Acceptable |
Production line |
STW-26BB |
6 |
2.0 |
Acceptable |
Pad printer |
SPD4050C |
7 |
8.0 |
Acceptable |
Testing Machinery:
Machine Name
Brand & Model No.
Quantity
Number of Year(s) Used
Condition
Spring tension tester |
TLS-S1000 |
2 |
10.0 |
Acceptable |
Rockwell hardness tester |
HR-150A |
1 |
10.0 |
Acceptable |
Delay test bench |
YONGGUANG |
30 |
3.0 |
Acceptable |
Leakage test bench |
YONGGUANG |
3 |
3.0 |
Acceptable |
High precision instant test machine |
YONGGUANG |
3 |
4.0 |
Acceptable |
Aging test bench |
JINGHUA |
16 |
8.0 |
Acceptable |
DC resistance tester |
TH2512B |
1 |
8.0 |
Acceptable |
Current character test bench |
LIMENG |
10 |
4.0 |
Acceptable |
Projecting apparatus |
WUXIGUANGXUE |
1 |
15.0 |
Acceptable |
Production Flow:
1.Assembling 1
2.Assembling 2
3.Pad printing
4.Assembling 3
5.Inspection 1
6.Inspection 2
7.Labeling
8.Packing 1
9.Packing 2
Certification:
Certified Picture
Certification Name
Certified By
Certificate No.
Product Name & Model No.
Available Date-Expired Date
|
CCC |
CQC |
2005010307140231 |
Miniature Circuit Breaker & TSM-63; Ue: AC230/400V (1P), AC400V (2P, 3P, 4P); In: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A; B, C, D type characteristics; Ics: 7.5 kA, Icn: 10 kA; No. of Poles: 1P, 2P, 3P, 4P |
2008/10/28 --- 2049/12/31 |
|
CCC |
CQC |
2002010307025193 |
Intelligent Circuit Breaker & TSW1-2000; Ui: 1000V; Ue: AC400V/690V; In: 630A, 800A, 1000A, 1250A, 1600A, 2000A; AC400V; Ics: 50kA,Icu: 80Ka, Icw: 50kA/1s; AC690v; Ics: 50kA, Icu:50kA, Icw: 40kA/1s;Over current trip mold; Electronic type; Use classes: B; No. of Poles: 3P, 4P |
2011/03/29 --- 2016/03/29 |
|
CCC |
CQC |
2002010307001805 |
Moulded Case Circuit Breaker & TSM2-100; Ui: 500V; Ue: AC230 (1P), AC400V(2P, 3P); In: 63A, 80A, 100A; Over current trip mold: Thermomagnetic type; Use classes: A; Ics: 7.5kA, Icu:10kA; No. of Poles: 1P, 2P, 3P |
2011/03/29 --- 2016/03/29 |