Liquid oxygen 175L Dewar

Cryogenic welded insulated cylinder:

liquid gas cylinder

Standard features list
standard 160180200
pressure MPHPMPHPMPHPVHP
Capability(L)Geometric volume175196210204
Size and (safety valve) open pressure settings
Safety valve settingpsig/ MPa230/1.6350/2.4230/1.6350/2.4230/1.6350/2.4500/3.45
diameterCM50.8
heightCM151.3161.3167.1
Empty weight(KG) 113.4126.9117.9136.1126.9145.1170
Full weight(KG)N2*234241253263271280286
O2*285290309318331339349
Ar*322325351357375380386
CO2* 303 331 353354
N2O* 293 321 343344
Gas volume under standard state(NM3)N2*979110810211510893
O2*120114134127143133123
Ar*117111130124139130120
CO2*-89-99-10593
N2O*-84-94-10088
functions
Daily evaporation rate(% per day)N221.91.852.0
O2- Ar1.41.31.21.4
CO2 - N2O-0.5-0.5-0.50.5
Air current(NM3/Hr)N2,O2,Ar9.29.210.5 9.2
CO2,N2O-2.9-2.9-2.92.9
Under the settings of safety valve(open pressure)
 

Booster coil1Gas valveexport gas2Fill/export liquid valvefill or export the liquid3Pressure control valvecontrol (turn on/off) the pressure control adjuster.4Vent valverelease the pressure5Combined pressure control adjusterautomatic control the pressure6-8Pressure gauge, safety valve, bursting disc9Liquid level detectorliquid capability of wielding insulation cylinder

New type workshop centralized gas feeder: dewar flask centralized gas feeding system sketch map:

New type workshop centralized gas feeder: dewar flask centralized gas feeding system sketch map: Features:1It is operated easily, used conveniently and accounted easily. Its highest working pressure is 1.6MPa.2The air flow is large and stable.Brief introduction about dewar flask:Firstly, outer structure of dewar flask: Dewar flask has four valves they are liquid valve, air valve, vent valve and pressurization valve as well as gas pressure gauge and level gauge.Secondly, usage: Your company is using the dewar flask. The firs step is to connect the pipe where the dewar flask liquid vavle lies with evaporator by the high pressure metallic tube. After the confirmation of connecting, you can turn on the liquid valve. If the gas pressure to the workshop can not meet the demand, please turn on the pressurization valve. A few minutes later, the pressure will rise to the using demand. Then you can make use of it. If the dewar flask has no liquid phase and the pressure of gas phase is only 5kg, it means that the gas in dewar flask has used up. Please turn off the using valve and stop using.Thirdly, some questions you should pay attention when using the storage1When the dewar flask storage has not been used, do not turn of the pressurization valve. You must check whether the pressurization valve is turned off tightly. Otherwise, the gas leak in the vessel.2You must turn off the pressurization valve when stop using. The pressurization valve is open only when it is used.3When thepressurization valve is turned open totally, the dewar flasks pressure gauge is no longer raise, than means there is no liquid phase only gas phase left in the vessel.