Item | Characteristic | |||||||||||||||||||
Operation Temperature Range | -40~+105C | -25~+105C | ||||||||||||||||||
Rated Working Voltage | 6.3~100VDC | 160~450VDC | ||||||||||||||||||
(120Hz 25C) Capacitance tolerance | ±20%(M) | |||||||||||||||||||
(25C) Leakage Current | I less 0.01Cvor5(µA) max
| L less 0.01CV+10(µA)
| ||||||||||||||||||
whichever is greater after 1 minute I: Leakage Current (µA) C: Rated Capacitance (µF) V: Working Voltage (V) | ||||||||||||||||||||
(25C) Surge Voltage | wv | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 | 160 | 200 | 250 | 350 | 400 | 450 | |||||
SV | 8 | 13 | 20 | 32 | 44 | 63 | 79 | 125 | 200 | 250 | 300 | 400 | 450 | 500 | ||||||
(120Hz 25C) Dissipation Factor (tanδ) | Add 0.02per 1000µF for more than 1000µF | |||||||||||||||||||
WV | 6.3 | 10 | 16 | 25 | 35 | 50 | 63 | 100 | 160 | 200 | 250 | 350 | 400 | 450 | ||||||
tan | 0.24 | 0.20 | 0.17 | 0.15 | 0.12 | 0.10 | 0.10 | 0.08 | 0.20 | 0.20 | 0.20 | 0.25 | 0.25 | 0.25 | ||||||
Low Temperature Stability | Impedance ratio at 120Hz | |||||||||||||||||||
Rated Voltage (V) | 6.3 | 10 | 16 | 25 | 35-100 | 160-250 | 350-450 | |||||||||||||
-25C/+25C | 4 | 3 | 2 | 2 | 2 | 8 | 12 | |||||||||||||
-40C/+25C | 10 | 8 | 6 | 4 | 3 | |||||||||||||||
Load Life | After 2000 hours application of W V at +105C the capacitor shall meet the following limits. | |||||||||||||||||||
Capacitance Change | Less ±20% of initial value | |||||||||||||||||||
Dissipation Factor | Less 150% of initial specified value | |||||||||||||||||||
Leakage Current | Less initial specified value | |||||||||||||||||||
Shelf Life | At 105C no voltage applied after 500 hours the capacitor shall meet the following limits | |||||||||||||||||||
Capacitance Change | Less 20% of initial value | |||||||||||||||||||
Dissipation Factor | Less 200% of initial specified value | |||||||||||||||||||
Leakage Current | Less 200% of initial specified value |