Ads by Google
12KW(LW12) | 15KW(LW15) | ||||||||
N | R | N | R | ||||||
Thermal Output:N=nominal-R=minimum | 12.0 | 3.6 | 15.0 | 3.6 | KW | ||||
heat output transferred to room air | 3.5 | 1.1 | 4.5 | 1.1 | KW | ||||
heat output transferred to water | 8.5 | 2.5 | 10.5 | 2.5 | KW | ||||
CO emission at 13% oxygen | 0.024 | 0.06 | 0.024 | 0.06 | % | ||||
efficiency | 90 | 90 | 90 | 90 | % | ||||
max.allowable water pressure during operation | 2 | 2 | bar | ||||||
safety valve | 3 | 3 | bar | ||||||
max.delivery temperature | 85 | 85 | °C | ||||||
nominal electrical power | 430 | 430 | W | ||||||
nominal voltage | 230 | 230 | V | ||||||
nominal frequency | 50/60 | 50/60 | Hz | ||||||
fuel | wood pellet | wood pellet | |||||||
fuel consumption per hour | 1.8 | 0.6 | 2 | 0.6 | kg/h | ||||
total capacity of flue gases | - | - | - | - | g/s | ||||
flue gas temperature | 100 | 80 | 100 | 80 | °C | ||||
flue draught pressure | 10 | 10 | 10 | 10 | Pa | ||||
expansion tank | 3 | 3 | L | ||||||
boiler capacity | 16 | 16 | ! | ||||||
connections | 1-3/4 | 1-3/4 | |||||||
receptacle capacity | 25 | 25 | kg | ||||||
burn time | 10 | 33 | 8 | 33 | h | ||||
operating power required | 150 | 150 | W | ||||||
flue gases outlet | ø80 | ø80 | mm | ||||||
combustion air intake | ø50 | ø50 | mm | ||||||
Weight of the structure including packing | 114 | 114 | kg | ||||||
Weight of the claddings kit including packing | see menu "Models" | kg |
pellet stove boiler