90W AC DC Power Adaptor
1. Input Requirements
1-1. Input Voltage
100 to 240Vac
1-2. Input Frequency
50/60Hz
1-3. Input Current
1.)1.8 A Max, AT 115Vac, Full load.
2.)1.0 A Max, AT 230Vac, Full load.
1-4. Efficiency
When100-240Vac line input voltage (120Vac), the efficiency shall be 83% or better under maximum load.
1-5.No Load Power Consumption
The internal power loss at no load shall be less than 1W AT 264Vac.
1-6. Inrush Current
1.)40A Max.(AT 115Vac, Cold Start.)
2.)80A Max.(AT 230Vac, Cold Start.)
1-7. Turn-On Time
3.5 Seconds Max. (AT 115Vac, Cold Start)
1-8. Hold Up Time
10m Seconds Min. (AT 115Vac Full Load).
1-9. Configuration
2- Wire input AC line (Line, Neutral,).
1-10. Line Regulation
The maximum voltage change on DC output shall be within tolerance when AC input voltages varies within the range specified±2%.
1-11. Input Protection Device
An adequate internal fuse on the AC input line shall be protected
1-12. Hi-Pot Test
Primary-Secondary: 1.8KVac For 3 Seconds. (Leakage Current 10mA)
Insulation resistance shall be more than 100Mohm AT 500Vdc between primary line, Neutral line and secondary between primary line neutral line and frame ground. (F.G)
2. Output Requirements
2-1. Output Voltage and Current
Output Voltage |
Tolerance |
Output Current | |
+12Vdc |
±5% | Min | Max |
0A | 7.5A |
2-2. Output Voltage Regulation
The total output voltage regulation shall be +5%, including the effects of line voltage variations, load current, ripple and noise. and the AC component of the load current.
2-3. Ripple and Noise
The power supply shall not exceed the following limits on the indicated voltage for 60Hz or
50Hz ripple, switching frequency ripple and noise measured with a 20MHz width
Output Voltage |
Ripple and Noise |
+12Vdc | 120mV(Max) |
Ripple and Noise: 50/60Hz Ripple +Switching Ripple and Noise
Ripple and noise are measured at the end of output cables which are added a 0.1uF(104) Ceramic capacitor and a 10uF Electrolytic capacitor (connect parallel)
2-4. Over Voltage Protection
The voltage will not exceed the upper trip limit. Use for ZENER diode
Output Voltage | Upper |
11.4Vdc~12.6Vdc |
|
2-5. Over Current Protection
When the adapter output current is over 14A should be shut down and no dangers or hazardous .It can auto recover when remove away the short.
2-6. Short Circuit Protection
A Short circuit place at output will not cause damage to adapter it can auto recover when remove away the short.
2-7. Leakage Current
0.5mA Max. (AT 264Vac 50Hz).
3. Environmental Requirements
Temperature
1.)Operating: 0°C to +40°C
2.)Storage : -20°C to +80°C
Humidity
1.)Operating: 10% to 90% non-condensing
2.)Storage : 5% to 95% non-condensing
Dimensions (Case Size )
Length: 140mm Width :60mm Height: 34mm
Weight
Power unit: <350g. (Max)